Posted on January 13, 2017 by BrandonF01 - Uncategorized
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications here: Mean Well Short Form Inverter
Mean Well 100~2500W Modified Sine Wave Features:
- High frequency design
- Input protections: Reverse polarity / Over and under voltage / Battery low alarm and shutdown
- Output protections: Short circuit / Overload / Over temp.
- With power ON/OFF switch and LED indicator
- Built-in remote ON/OFF control for 1000~2500W (optional)
- Built-in USB interface and without fan for 100W
- Input and output fully isolation
- Low power consumption (standby)
- LVD meet EN60950-1 and e13 mark
- EMC meet EN61000-4-2,3, EN55022
- 1 year warranty
Model Name |
A301 |
A302 |
DC input rated voltage |
12.5VDC |
25.0VDC |
AC output voltage / Frequency |
110VAC(rms) / 60Hz or 230VAC(rms) / 50Hz |
Max. output power |
100W, 150W, 300W, 600W, 1000W, 1500W, 2500W |
USB output power |
5VDC / 500mA (100W only) |
AC output regulation |
±10% of rated output voltage |
Bat. low alarm |
10±0.5VDC |
20.5±1.0VDC |
Bat. low shut down |
9.5±0.5VDC |
19.5±1.0VDC |
I/P over voltage protection |
15~17VDC |
30~32VDC |
Working temperature |
0~+40OC (0~+25OC for 2500W) |
Safety standards |
Compliance to EN60950-1(LVD) |
EMC standards |
Compliance to EN55022 class B, e-mark, EN61000-4-2,3 |
100W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-100-F3 |
100W |
10-15 |
230 / 50 |
TYPE-3 |
90% |
A302-100-F3 |
100W |
21-30 |
230 / 50 |
TYPE-3 |
90% |
150W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-150-B2 |
150W |
10-15 |
110 / 60 |
TYPE-2 |
78% |
A301-150-F3 |
150W |
10-15 |
230 / 50 |
TYPE-3 |
78% |
A302-150-B2 |
150W |
21-30 |
110 / 60 |
TYPE-2 |
82% |
A302-150-F3 |
150W |
21-30 |
230 / 50 |
TYPE-3 |
82% |
300W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-300-B2 |
300W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-300-F3 |
300W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-300-B2 |
300W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-300-F3 |
300W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
600W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-600-B2 |
600W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-600-F3 |
600W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-600-B2 |
600W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-600-F3 |
600W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
1000W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-1K0-B2 |
1000W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-1K0-F3 |
1000W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-1K0-B2 |
1000W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-1K0-F3 |
1000W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
1500W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-1K7-B2 |
1500W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-1K7-F3 |
1500W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-1K7-B2 |
1500W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-1K7-F3 |
1500W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
2500W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-2K5-B4 |
2500W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-2K5-F3 |
2500W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-2K5-B4 |
2500W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-2K5-F3 |
2500W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
100W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-100-F3 |
100W |
10-15 |
230 / 50 |
TYPE-3 |
90% |
A302-100-F3 |
100W |
21-30 |
230 / 50 |
TYPE-3 |
90% |
150W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-150-B2 |
150W |
10-15 |
110 / 60 |
TYPE-2 |
78% |
A301-150-F3 |
150W |
10-15 |
230 / 50 |
TYPE-3 |
78% |
A302-150-B2 |
150W |
21-30 |
110 / 60 |
TYPE-2 |
82% |
A302-150-F3 |
150W |
21-30 |
230 / 50 |
TYPE-3 |
82% |
300W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-300-B2 |
300W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-300-F3 |
300W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-300-B2 |
300W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-300-F3 |
300W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
600W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-600-B2 |
600W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-600-F3 |
600W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-600-B2 |
600W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-600-F3 |
600W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
1000W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-1K0-B2 |
1000W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-1K0-F3 |
1000W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-1K0-B2 |
1000W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-1K0-F3 |
1000W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
1500W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-1K7-B2 |
1500W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-1K7-F3 |
1500W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-1K7-B2 |
1500W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-1K7-F3 |
1500W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
2500W |
Model Name |
Continue |
Input |
Output |
Output |
Effi. |
|
power |
VDC |
VAC / Hz |
socket |
|
A301-2K5-B4 |
2500W |
10-15 |
110 / 60 |
TYPE-2 |
82% |
A301-2K5-F3 |
2500W |
10-15 |
230 / 50 |
TYPE-3 |
82% |
A302-2K5-B4 |
2500W |
21-30 |
110 / 60 |
TYPE-2 |
85% |
A302-2K5-F3 |
2500W |
21-30 |
230 / 50 |
TYPE-3 |
85% |
Mean Well 100~2500W Modified Sine Wave Inverters
Posted on July 9, 2016 by BrandonF01 - Uncategorized
To check availability or to speak with a Power 277 Specialist please call Toll Free: (877) 878-2348 | Int’l: (001) 702-987-3111
Posted on July 8, 2016 by BrandonF01 - Uncategorized
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for NSD05 / NSD10-S / NSD10-D / NSD15-S / NSD15-D / NID30 / NID60 above.
NSD05-S Series Features:
5W DC-DC Regulated Single Output
- Wide 4:1 DC input range
- Protections: Short circuit / Overload / Over voltage
- 1000VDC 1/O isolation
- Cooling by free air convection
- Built-in remote ON-OFF contro
- 100% full load burn-in test
- Low cost
- High reliability
- 2 years warranty
MODEL |
NSD05-12S3 |
NSD05-12S5 |
NSD05-12S12 |
NSD05-12S15 |
NSD05-48S3 |
NSD05-48S5 |
NSD05-48S12 |
NSD05-48S15 |
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
12V |
15V |
3.3V |
5V |
12V |
15V |
RATED CURRENT |
1.2A |
1A |
0.42A |
0.33A |
1.2A |
1A |
0.42A |
0.33A |
CURRENT RANGE |
0 ~ 1.2A |
0 ~ 1A |
0 ~ 0.42A |
0 ~ 0.33A |
0 ~ 1.2A |
0 ~ 1A |
0 ~ 0.42A |
0 ~ 0.33A |
RATED POWER |
3.96W |
5W |
5.04W |
4.95W |
3.96W |
5W |
5.04W |
4.95W |
CAPACITIVE LOAD (max.) |
1000uF |
1000uF |
120uF |
120uF |
1000uF |
1000uF |
120uF |
120uF |
RIPPLE & NOISE (max.) Note.2 |
75mVp-p |
VOLTAGE TOLERANCE Note.3 |
±2.0% max. |
LINE REGULATION |
±1.0% |
LOAD REGULATION |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
SETUP TIME |
80ms/RATED DC INPUT at full Load |
|
INPUT |
RATED DC INPUT |
12VDC |
48VDC |
VOLTAGE RANGE |
9.2 ~ 36VDC |
18 ~ 72VDC |
EFFICIENCY (Typ.) |
72% |
76% |
82% |
83% |
75% |
78% |
83% |
85% |
DC CURRENT |
0.7A/12VDC |
0.2A/48VDC |
SHUTDOWN IDLE CURRENT |
5mA/12VDC 5mA/48VDC |
PROTECTION |
OVERLOAD |
Above 105% rated output power |
Protection type : Over power limiting, recovers automatically after fault condition is removed |
OVER VOLTAGE(CLAMP) |
3.8 ~ 4.6V |
5.6 ~ 6.8V |
13.5 ~ 16.5V |
16.2 ~ 19.8V |
3.8 ~ 4.6V |
5.6 ~ 6.8V |
13.5 ~ 16.5V |
16.2 ~ 19.8V |
SHORT CIRCUIT |
Recovers automatically after fault condition is removed |
FUNCTION |
ON/OFF CONTROL |
Logic “1” or open circuit : ON Logic “0” or short to PIN2 : OFF |
ENVIRONMENT |
WORKING TEMP. |
-25 ~ +70? |
WORKING HUMIDITY |
0% ~ 95% RH max. |
STORAGE TEMP., HUMIDITY |
-40 ~ +85?, 0 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/? (0~60?) |
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
IEC60950-1 CB approved by TUV |
ISOLATION VOLTAGE |
I/P-O/P:1KVDC |
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH |
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8; EN55024, light industry level, criteria A |
OTHERS |
MTBF |
914.4K hrs min. MIL-HDBK-217F (25?) |
DIMENSION |
40.6*25.4*8.3mm (1.6″*1″*0.327″) (L*W*H) |
PACKING |
0.007Kg; 700pcs/5.9Kg/0.97CUFT |
NOTE |
All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25? of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EM1 testing of component power supplies.” (as available on http://www.meanwell.com) To insure proper operation, a 47uF/100V electrolytic capacitor with Esr <1? must be added to the input line. 6.EMC filter suggestion(TBD): 5.5uH + + + Vin 680uF PSU Vo - - |
Posted on January 9, 2017 by BrandonF01 - Uncategorized
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can view the entire Mean Well Battery Charger Catalog here: Mean Well Short Form Inverter
Mean Well 300~1000W Stationary Battery Charger Features:
- Universal AC input / Full range (PB-600/1000)
- AC input range selectable by switch (PB-300/360)
- Built-in passive PFC function (PB-300P/360P)
- Built-in active PFC function (PB-600/1000)
- 3 poles AC inlet IEC320-C14
- Cooling by built-in DC fan (except for PB-300)
- Built-in ON/OFF power switch
- Built-in remote ON/OFF control
- 2/3/8 stage smart charger for PB-600/1000
- Protections: Short circuit / Over voltage / Over temperature / Reverse polarity
- LED indicator for charging status
- 3 years warranty
Model Name |
PB-300 |
PB-360 |
PB-600 |
PB-1000 |
AC input voltage range |
90~132VAC / 180~264VAC selectable by switch |
90~264VAC |
Charge style |
3 stage |
2/3/8 stage (selectable) |
Over voltage protection |
Range |
108%~125% |
112%~125% |
110%~125% |
Type |
shut off output voltage, re-power on to recover |
Withstand voltage |
I/P-O/P: 3kVAC, 1 minute |
Working temperature |
-10~+50oC |
-20~+60oC |
Safety standards |
PB-300/360: UL60950-1, CB IEC60335-2-29 (except for 48V) PB-600: UL1012, TUV EN60950-1 (48V only), TUV EN60335-2-29 (except for 48V) PB-1000: UL60950-1, TUV EN60950-1 |
EMC standards |
EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3 (except for PB-300N/360N) |
DC output connector |
Terminal block 2P |
Terminal block 3P |
Model Name Wattage Output Effi. PB-300 -12 300W 14.4V, 0~20.85A 85% PB-300 -24 302W 28.8V, 0~10.5A 86% PB-300 -48 305W 57.6V, 0~5.3A 88% =P, N ; P: with PFC, N: non PFC |
Model Name Wattage Output Effi. PB-600-12 576W 14.4V, 0~40.0A 86% PB-600-24 605W 28.8V, 0~21.0A 87% PB-600-48 605W 57.6V, 0~10.5A 89% |
Model Name Wattage Output Effi. PB-360 -12 350W 14.4V, 0~24.3A 85% PB-360 -24 360W 28.8V, 0~12.5A 86% PB-360 -48 360W 57.6V, 0~6.25A 87% =P, N ; P: with PFC, N: non PFC |
Model Name Wattage Output Effi. PB-1000-12 864W 14.4V, 0~60.0A 85% PB-1000-24 999W 28.8V, 0~34.7A 88% PB-1000-48 1002W 57.6V, 0~17.4A 89% |
300~1000W Stationary Battery Charger Digital Spec Image
Posted on July 6, 2016 by BrandonF01 - Uncategorized
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for GS15A / GS15B / GST18A / GST18B / GST25A / GST25B / GST36B / GST40A / GST60A / GST90A / GST120A / GST160A / GST220A / GST280A / GP25A / GP25B / GP50A above.
GS15A Series Features:
15W AC-DC Industrial Adaptor
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14
- No load power consumption <0.075W
- Energy efficiency Level Ⅵ
- Comply with EISA 2007/DoE, EU ErP and meet CoC version 5
- Class I power ( with earth pin)
- Protections: Short circuit / Overload / Over voltage
- Pass LPS
- Fully enclosed plastic case
- 2 years warranty
ORDER NO. |
GS15A-1P1J |
GS15A-11P1J |
GS15A-2P1J |
GS15A-3P1J |
GS15A-4P1J |
GS15A-5P1J |
GS15A-6P1J |
GS15A-8P1J |
OUTPUT |
SAFETY MODEL NO. |
GS15A-1 |
GS15A-1-1 |
GS15A-2 |
GS15A-3 |
GS15A-4 |
GS15A-5 |
GS15A-6 |
GS15A-8 |
DC VOLTAGE Note.2 |
5V |
7.5V |
9V |
12V |
15V |
18V |
24V |
48V |
RATED CURRENT |
2.40A |
1.60A |
1.66A |
1.25A |
1.00A |
0.83A |
0.625A |
0.31A |
CURRENT RANGE |
0 ~ 2.40A |
0 ~ 1.60A |
0 ~1.66A |
0 ~ 1.25A |
0 ~ 1.00A |
0 ~ 0.83A |
0 ~ 0.625A |
0 ~ 0.31A |
RATED POWER |
12W |
12W |
15W |
15W |
15W |
15W |
15W |
15W |
RIPPLE & NOISE (max.) Note.3 |
50mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
100mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
VOLTAGE TOLERANCE Note.4 |
±5.0% |
±5.0% |
±5.0% |
±3.0% |
±3.0% |
±3.0% |
±2.0% |
±2.0% |
LINE REGULATION Note.5 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION Note.6 |
±5.0% |
±5.0% |
±5.0% |
±3.0% |
±3.0% |
±3.0% |
±2.0% |
±2.0% |
SETUP, RISE, HOLD UP TIME |
3000ms, 50ms, 16ms at full load |
INPUT |
VOLTAGE RANGE |
90 ~ 264VAC 135 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
80% |
82.5% |
85% |
85% |
85% |
85% |
85.5% |
87% |
AC CURRENT |
0.5A / 100VAC |
INRUSH CURRENT (max.) |
50A / 230VAC |
LEAKAGE CURRENT(max.) |
0.25mA / 240VAC |
PROTECTION |
OVERLOAD |
105 ~ 250% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
>120% rated output voltage |
Protection type : Clamp by zener diode |
ENVIRONMENT |
WORKING TEMP. |
0 ~ +50? (Refer to “Derating Curve”) |
WORKING HUMIDITY |
20% ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20 ~ +85?, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03% / ? (0 ~ 40?) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
SAFETY & EMC (Note. 7) |
SAFETY STANDARDS |
UL60950-1, CSA C22.2, TUV EN60950-1 approved |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC , I/P-FG:1.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25?/ 70% RH |
EMC EMISSION |
Compliance to EN55022 Class B, EN61000-3-2,3, FCC part 15 Class B |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A |
OTHERS |
MTBF |
500Khrs min. MIL-HDBK-217F(25?) |
DIMENSION |
100*58.5*32.8mm (L*W*H) |
PACKING |
190g ; 90pcs / 18Kg / CARTON |
CONNECTOR |
PLUG |
See page 2 ; Other type available by customer requested |
CABLE |
See page 2 ; Other type available by customer requested |
NOTE |
1.All parameters are specified at 230VAC input, rated load, 25? 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 0% to 100% rated load. 7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) |
GS15A Specification Image
Posted on July 8, 2016 by BrandonF01 - Uncategorized
-
100W Modified Sine Wave DC-AC Power Inverter – A301/302-100 Series
Features:
- Built-in USB interface
- Cooling by free air convection(without fan)
- Slim size can fit in with the cup holder on vehicles
- High efficiency up to 90%
- 12V or 24V DC input
- Input voltage range: -15% – +25%
- Output voltage regulation:±10%
- Protections: Input reverse polarity/Bat. Low shutdown/Over voltage/ Over load/Over temperature/Output short
- Output waveform: Modified sine wave
- Topology: Microprocessor
- Approvals: e13/ CE
- 1 year warranty
Specification
ORDER NO.
| A301-100-F3
| A302-100-F3
|
OUTPUT
| SAFETY MODEL NO.
| A-100-150W(N)
|
AC RATED VOLTAGE Note.1
| 230V
|
RATED POWER
| 100W
|
SURGE POWER
| 200W
|
WAVEFORM
| Modified Sine Wave
|
FREQUENCY
| 50Hz±1%
|
AC REGULATION
| ±10%
| ±10%
|
STANDARD RECEPTACLES
| Europe*1ea
|
LED INDICATOR
| Dual-color indicator display for power on / failure status
|
USB POWER
| 5VDC / 500mA (max.)
| 5VDC / 300mA (max.)
|
INPUT
| DC CURRENT
| 15A
| 10A
|
NO LOAD CURRENT DRAW
| 0.25A
| 0.2A
|
DC VOLTAGE
| 12V
| 24V
|
VOLTAGE RANGE
| 10 ~ 15VDC
| 21 ~ 30VDC
|
EFFICIENCY (Typ.)
| 90%
|
DC CONNECTOR
| 650±50mm Cigarette plug*1ea
|
FUSE
| 15A* 1ea
| 10A* 1ea
|
PROTECTION
| BAT. LOW SHUTDOWN
| 10±0.5V
| 19.5±1V
|
OVER VOLTAGE
| 15 ~ 17V
| 30 ~ 32V
|
OVER TEMPERATURE
| 60±5? / 140±9oF (case)
|
OUTPUT SHORT
| Shut-off
|
REVERSE. POLARITY
| By fuse open
|
ENVIRONMENT
| WORKING TEMP.
| 0 ~ +30?@100% load, 40?@ 50% load
|
WORKING HUMIDITY
| 20% ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
| -30 ~ +70? / -22 ~ +158oF, 10 ~ 95% RH
|
TEMP. COEFFICIENT
| ±0.05% / ? (0 ~ 50?)
|
SAFETY & EMC
| ISOLATION RESISTANCE
| I/P-O/P:100M Ohms min./ 500VDC / 25?/ 70% RH
|
EMI RADIATION
| Compliance to EN55022 class B, 72/ 245/ CEE, 2006/96/CE
|
EMS IMMUNITY
| Compliance to EN61000-4-2,3
|
LVD
| Compliance to EN60950-1
|
OTHERS
| DIMENSION
| ?65*170mm (Diameter*L)
|
PACKING
| 0.55Kg ; 30pcs / 17.5Kg / CARTON
|
COOLING
| By air convection
|
APPLICATIONS
| Home appliance, office and portable equipment and vehicle …etc.
|
NOTE
| 1. AC rated output voltage is measured at 12.5VDC, 25VDC input voltage. |
-
150W Modified Sine Wave DC-AC Power Inverter – A-301/302-150 Series
Features:
- Power ON-OFF switch
- Input voltage range: -15% – +25%
- Output voltage regulation:±10%
- Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/ Over temp./Output short/Input polarity reverse/Over load.
- Output waveform: Modified sine wave
- Topology: Microprocessor
- Approvals: e13/ CE
- 1 year warranty
Specifications
ORDER NO.
| A301-150-B2
| A302-150-B2
|
OUTPUT
| SAFETY MODEL NO.
| A-300-150W
| A-300-150W
|
AC VOLTAGE
| 110V
| 110V
|
RATED POWER
| 150W
| 150W
|
SURGE POWER
| 300W
| 300W
|
WAVEFORM
| Modified sine wave
| Modified sine wave
|
FREQUENCY
| 60Hz±1%
| 60Hz±1%
|
AC REGULATION
| ±10%
| ±10%
|
STANDARD RECEPTACLES
| TYPE-2* 1ea
| TYPE-2* 1ea
|
LED INDICATOR
| Green LED for power on
|
INPUT
| DC CURRENT
| 15A
| 10A
|
NO LOAD CURRENT DRAW
| 0.25A
| 0.2A
|
DC VOLTAGE
| 12V
| 24V
|
VOLTAGE RANGE
| 10 ~ 15VDC
| 21 ~ 30VDC
|
EFFICIENCY (Typ.)
| 78%
| 82%
|
DC CONNECTOR
| 700mm Cigarette plug*1ea
| 700mm Cigarette plug*1ea
|
FUSE
| 15A* 1ea
| 10A* 1ea
|
PROTECTION
| BAT. LOW ALARM
| 10±0.5V
| 20.5±1V
|
BAT. LOW SHUTDOWN
| 9.5±0.5V
| 19.5±1V
|
OVER VOLTAGE
| 15 ~ 17V
| 30~32V
|
OVER TEMPERATURE
| 60±5? / 140±9oF
|
OUTPUT SHORT
| Shut-off; Broken
|
BAT. POLARITY
| By fuse open
|
ENVIRONMENT
| WORKING TEMP.
| 0 ~ 30?@100% load, 40?@50% load
|
WORKING HUMIDITY
| 20% ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
| -30 ~ +70? / -22 ~ +158oF, 10 ~ 95% RH
|
TEMP. COEFFICIENT
| ±0.05% / ? (0 ~ 50?)
|
SAFETY & EMC
| ISOLATION RESISTANCE
| I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH
|
EMI RADIATION
| Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE
|
EMS IMMUNITY
| Compliance to EN61000-4-2,3
|
LVD
| Compliance to EN60950
|
OTHERS
| MTBF
| 200Khrs min. MIL-HDBK-217F(25?)
|
DIMENSION
| 122*73*45mm (L*W*H)
|
PACKING
| 0.5Kg ; 30pcs / 17Kg / CARTON
|
COOLING
| By air convection
|
APPLICATIONS
| Home appliance, Power tools, Office and Portable equipment and Vehicle …etc.
|
AC Output Receptacles (optional) |
AC Wavefrom Modified Sine Wave – CAUTION Always place the inverter in an environment which is:
- (A)Well ventilated
- (B)Not exposed to direct sunlight or heat source (C)Out of reach from children
- (D)Away from water/moisture oil or grease (E)Away from any flammable substance
Features:
- Power ON-OFF switch
- Input voltage range: -15% – +25%
- Output voltage regulation:±10%
- Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/ Over temp./Output short/Input polarity reverse/Over load.
- Output waveform: Modified sine wave
- Topology: Microprocessor
- Approvals: e13/ CE
- 1 year warranty
ORDER NO.
| A301-150-F3
| A302-150-F3
|
OUTPUT
| SAFETY MODEL NO.
| A-300-150W
| A-300-150W
|
AC VOLTAGE
| 230V
| 230V
|
RATED POWER
| 150W
| 150W
|
SURGE POWER
| 300W
| 300W
|
WAVEFORM
| Modified Sine Wave
| Modified sine wave
|
FREQUENCY
| 50Hz±1%
| 50Hz±1%
|
AC REGULATION
| ±10%
| ±10%
|
STANDARD RECEPTACLES
| TYPE-3* 1ea
| TYPE-3* 1ea
|
LED INDICATOR
| Dual-color indicators display for power on / failure status
|
INPUT
| DC CURRENT
| 15A
| 10A
|
NO LOAD CURRENT DRAW
| 0.25A
| 0.2A
|
DC VOLTAGE
| 12V
| 24V
|
VOLTAGE RANGE
| 10 ~ 15VDC
| 21 ~ 30VDC
|
EFFICIENCY (Typ.)
| 78%
| 82%
|
DC CONNECTOR
| 700mm Cigarette plug*1ea
| 700mm Cigarette plug*1ea
|
FUSE
| 15A* 1ea
| 10A* 1ea
|
PROTECTION
| BAT. LOW ALARM
| 10±0.5V
| 20.5±1V
|
BAT. LOW SHUTDOWN
| 9.5±0.5V
| 19.5±1V
|
OVER VOLTAGE
| 15 ~ 17V
| 30 ~ 32V
|
OVER TEMPERATURE
| 60±5? / 140±9oF
|
OUTPUT SHORT
| Shut-off
|
BAT. POLARITY
| By fuse open
|
ENVIRONMENT
| WORKING TEMP.
| 0 ~ +30?@100% load, 40?@ 50% load
|
WORKING HUMIDITY
| 20% ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
| -30 ~ +70? / -22 ~ +158oF, 10 ~ 95% RH
|
TEMP. COEFFICIENT
| ±0.05% / ? (0 ~ 50?)
|
SAFETY & EMC
| ISOLATION RESISTANCE
| I/P-O/P:100M Ohms min./ 500VDC / 25?/ 70% RH
|
EMI CONDUCTION & RADIATION
| Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE
|
EMS IMMUNITY
| Compliance to EN61000-4-2,3
|
LVD
| Compliance to EN60950
|
OTHERS
| MTBF
| 200Khrs min. MIL-HDBK-217F (25?)
|
DIMENSION
| 165*94*69mm (L*W*H)
|
PACKING
| 0.8Kg ; 20pcs / 15Kg / CARTON
|
COOLING
| By air convection
|
APPLICATIONS
| Home appliance, Power tools, Office and Portable equipment and Vehicle …etc.
|
AC Output Receptacles (optional) |
-
Additional PDF Specifications
Posted on July 6, 2016 by BrandonF01 - Uncategorized
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for OWA-60U / OWA-60E / OWA-90U / OWA-90E / OWA-120U / OWA-120E above.
OWA-60U Series Features / Applications:
60W Single Output Moistureproof Adaptor
- Universal AC input / Full range (up to 264VAC)
- High efficiency up to 91%
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Class Ⅱ power unit, no FG
- Fully isolated plastic case
- Fanless design, cooling by free air convection
- No load power consumption <0.15W
- Comply with EISA 2007 DoE and NRCan
- UL LISTED, suitable for dry and damp locations
- 5 years warranty
- Indoor LED lighting
- LED decorative lighting
- General electronic products in dusty or humid environment
OWA-60U Description
OWA-60U is one 60W single-output external LED power supply series. Pairing the North American type of AC plug and the prevailing DC connectors, OWA-60U, working like an adaptor, simplifies the connection with LED lighting fixtures without extra wiring efforts. The entire series is certified with the “UL LISTED” for dry and damp locations.
As a class Ⅱ (no FG) design, the enclosure of OWA-60U is a 94V-0 flame retardant plastic case. The interior is fully potted with silicone that enhances the heat dissipation. With the working efficiency up to 91%, OWA-60U is cooled by free air convection; the working temperature ranges from -35℃ to +70℃.
MODEL |
OWA-60U-12 |
OWA-60U-15 |
OWA-60U-20 |
OWA-60U-24 |
OWA-60U-30 |
OWA-60U-36 |
OWA-60U-42 |
OWA-60U-48 |
OWA-60U-54 |
OUTPUT |
DC VOLTAGE |
12V |
15V |
20V |
24V |
30V |
36V |
42V |
48V |
54V |
CONSTANT CURRENT REGION |
6 ~ 12V |
7.5 ~ 15V |
10 ~ 20V |
12 ~ 24V |
15 ~ 30V |
18 ~ 36V |
21 ~ 42V |
24 ~ 48V |
27 ~ 54V |
RATED CURRENT |
5A |
4A |
3A |
2.5A |
2A |
1.67A |
1.5A |
1.25A |
1.12A |
RATED POWER |
60W |
60W |
60W |
60W |
60W |
60.12W |
63W |
60W |
60.48W |
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
250mVp-p |
250mVp-p |
350mVp-p |
VOLTAGE TOLERANCE Note.3 |
±4.0% |
±4.0% |
±4.0% |
±3.0% |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LOAD REGULATION |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
SETUP, RISE TIME Note.4 |
500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load |
HOLD UP TIME (Typ.) |
10ms at full load 115VAC / 230VAC |
INPUT |
VOLTAGE RANGE |
90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
115VAC |
87% |
88% |
88% |
88.5% |
88.5% |
88.5% |
88.5% |
88.5% |
89% |
230VAC |
88% |
89% |
89% |
90% |
90% |
90% |
90% |
91% |
91% |
AC CURRENT (Typ.) |
1.2A / 115VAC 0.7A / 230VAC |
|
COLD START 35A(twidth=750?s measured at 50% Ipeak) at 115VAC |
INRUSH CURRENT (Typ.) |
COLD START 65A(twidth=750?s measured at 50% Ipeak) at 230VAC |
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT |
<0.25mA / 240VAC |
PROTECTION |
OVER CURRENT |
95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
14 ~ 16V |
17.5 ~ 23V |
23 ~ 27V |
28 ~ 34V |
34 ~ 40V |
41 ~ 50V |
46 ~ 54V |
53 ~ 62V |
58 ~ 66V |
Protection type : Shut down o/p voltage, re-power on to recover |
OVER TEMPERATURE |
Shut down o/p voltage, re-power on to recover |
ENVIRONMENT |
WORKING TEMP. |
-35 ~ +70? (Refer to “Derating Curve”) |
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40 ~ +80?, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/? (0 ~ 50?) |
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC |
SAFETY STANDARDS |
UL8750 listed; CSA C22.2 No.250.13-12(except for 42V,48V,54V); IP67 approved for power body |
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC |
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH |
EMC EMISSION |
Compliance to FCC Part15 |
OTHERS |
MTBF |
292.8K hrs min. MIL-HDBK-217F (25?) |
DIMENSION |
130*53*35mm |
PACKING |
0.41Kg; 16pcs/6.8Kg/0.85CUFT |
NOTE |
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25? of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. |
Driving Methods of the LED Module
There are two major kinds of LED drive method, “direct drive” and “with LED driver”. A typical LED power supply may either work in “constant voltage mode (CV)” or “constant current mode (CC)” to drive the LEDs.
Mean Well’s LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
Posted on July 9, 2016 by BrandonF01 - Uncategorized
Posted on July 9, 2016 by BrandonF01 - Uncategorized
Posted on July 8, 2016 by BrandonF01 - Uncategorized
Mean Well Solar Inverter with MPPT Function – ISI- 500 Specifications
Features:
- High surge power up to 1000W
- Power ON-OFF switch
- Protections: Bat. low alarm / Bat. low shutdown / Over temp. / Output short / Input polarity reverse / Over load
- High frequecny design
- AC Output voltage regulation : 10%
- AC Output wavform : Modified sine wave
- Modified models available(optional): 100/115/120VAC or 200/220/240VAC
- Cooling fan ON-OFF control
- Built-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.)
- Built-in battery low relay contact
- LED indicator for operation status
- 2 years warranty
MODEL
| ISI-500-112
| ISI-500-124
| ISI-500-148
| ISI-500-212
| ISI-500-224
| ISI-500-248
|
OUTPUT
| RATED POWER
| 350W
| 500W
| 500W
| 350W
| 500W
| 500W
|
MAXIMUM OUTPUT POWER (Typ.)
| 550W for 1 minute / surge power 1000W for 30 cycles (112, 212 models : 385W for 1 minute / surge power 700W for 30 cycles)
|
WAVEFORM
| Modified sine wave
|
AC VOLTAGE
| 110V
| 230V
|
FREQUENCY
| 60Hz 0.5Hz
| 50Hz 0.5Hz
|
AC REGULATION
| 10%
|
LED INDICATOR
| Green: Inverter OK Green (flashing): Inverter OK and charging Red: abnormal
|
INPUT
| BAT. VOLTAGE
| 12V
| 24V
| 48V
| 12V
| 24V
| 48V
|
VOLTAGE RANGE Note.3,4
| 10.5 ~ 15VDC
| 21 ~ 30VDC
| 42 ~ 60VDC
| 10.5 ~ 15VDC
| 21 ~ 30VDC
| 42 ~ 60VDC
|
DC CURRENT (Typ.)
| 35A
| 25A
| 12.5A
| 35A
| 25A
| 12.5A
|
NO LOAD CURRENT DRAW
| 0.8A
| 0.4A
| 0.2A
| 0.8A
| 0.4A
| 0.2A
|
OFF MODE CURRENT DRAW
| 1mA
|
EFFICIENCY (Typ.) Note.1
| 85%
| 87%
| 87%
| 86%
| 88%
| 88%
|
BATTERY TYPE
| Open & sealed Lead Acid
|
SOLAR PANEL INPUT
| VOLTAGE RANGE
| 20 ~ 40V
| 35 ~ 80V
| 70 ~ 160V
| 20 ~ 40V
| 35 ~ 80V
| 70 ~ 160V
|
MAX. SHORT CIRCUIT CURRENT
| 15A
| 15A
| 7.5A
| 15A
| 15A
| 7.5A
|
RATED CHARGE POWER (Typ.)
| 350W
| 500W
| 500W
| 350W
| 500W
| 500W
|
SOLAR CHARGER
| MAX. CHARGE VOLTAGE
| 14V
| 28V
| 56V
| 14V
| 28V
| 56V
|
MAX. CHARGE CURRENT
| 25A
| 20A
| 10A
| 25A
| 20A
| 10A
|
BATTERY INPUT PROTECTION
| FUSE
| 40A
| 30A
| 15A
| 40A
| 30A
| 15A
|
BAT. LOW ALARM Note.4
| 11V
| 22V
| 44V
| 11V
| 22V
| 44V
|
BAT. LOW SHUTDOWN Note.4
| 10.5V
| 21V
| 42V
| 10.5V
| 21V
| 42V
|
REVERSE POLARITY
| By internal fuse
|
OUTPUT PROTECTION
| OVER TEMPERATURE
| 70 10
| 65 10
|
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect on power transistor
|
OUTPUT SHORT
| Protection type : Shut down o/p voltage, re-power on to recover
|
OVER LOAD
| Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec.
|
FUNCTION
| BAT. LOW RELAY CONTACT
| Open : Battery low ; Short : Battery ok
|
ENVIRONMENT
| WORKING TEMP. Note.2
| -20 ~ +40 @ 100% load ; 60 @ 50% load
|
WORKING HUMIDITY
| 20% ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
| -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
|
VIBRATION
| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
|
EMC
| LVD
| None
| EN60950-1
|
WITHSTAND VOLTAGE
| Bat. I/P – AC O/P:3.0KVAC AC O/P – FG:1.5KVAC
|
ISOLATION RESISTANCE
| Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
|
EMC EMISSION
| Compliance to FCC part 15 class A
| Compliance to EN55022 class A
|
EMS IMMUNITY
| None
| Compliance to EN61000-4-2,3,8
|
OTHERS
| MTBF
| 81.1K hrs min. MIL-HDBK-217F (25oC)
|
DIMENSION
| 205*158*67mm (L*W*H)
|
PACKING
| 1.92Kg; 6pcs/12.5Kg/1.55CUFT
|
NOTE
| 3 , 3 , 6 , 3 I , |
AC Output Receptacles (optional)
Receptacle type
|
|
|
|
|
|
|
TYPE-A (Standard)
| TYPE-B (Standard)
| TYPE-C (Optional)
| TYPE-D (Optional)
| TYPE-E (Optional)
| TYPE-U (Optional)
|
Country
| USA
| EUROPE
| AUSTRALIA
| U.K
| JAPAN
| UNIVERSAL
|
Certificate
|
|
|
|
|
| Non |
Pin No.
| Assignment
| Pin No.
| Assignment
|
1
| FG
| 4
| Battery POS(+)
|
2
| Solar POS(+)
| 5
| Battery NEG(-)
|
3
| Solar NEG(-)
|
| |
Mean Well Solar Inverter with MPPT Function – ISI- 501 Specifications
Features | Applications
- True sine wave output (THD<3%)
- High surge power up to 1000W
- High efficiency up to 88%
- High frequency design
- Thermostatically controlled cooling fan
- Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload
- Built-in 500W MPPT solar charger, MPPT efficiency:98%(Typ.)
- Built-in remote ON-OFF control
- Built-in battery low relay contact
- LED indicator for operation status and battery capacity
- 3 years warranty
Description:
- Home appliance
- Power tools
- Portable equipment
- Yacht
- Vehicle
ISI-501 series integrates a DC/AC True Sine Wave Inverter and a MPPT charger. This series is a high performance true sine wave DC/AC inverter which converts the DC electricity from a system consisting of batteries and solar panels. ISI-501 is not only a high frequency designed inverter but also fully digitally controlled by an advanced microprocessor. With true sine wave output, ISI-501 series can provide 500W continuously, 550W for 60 seconds, and 1000W for 30 AC-cycles. This series incorporates a MPPT solar charger, including the constant current and constant voltage charging characteristics.
AC Output Receptacles (Optional)
Receptacle type
|
|
|
|
|
|
|
|
TYPE-A
| TYPE-B
| TYPE-C
| TYPE-D
| TYPE-E
| TYPE-F
| TYPE-U
|
Standard
| Standard
| Optional
| Optional
| Optional
| Optional
| Optional
|
Country
| USA
| EUROPE
| AUSTRALIA
| U.K
| JAPAN
| GFCI
| UNIVERSAL
|
Certificate
|
|
|
|
|
|
| Non |
Specifications
MODEL
|
ISI-501-112?
|
ISI-501-124?
|
ISI-501-148?
|
ISI-501-212?
|
ISI-501-224?
|
ISI-501-248?
|
INVERTER SECTION
|
OUTPUT
|
RATED POWER
|
450W
|
500W
|
450W
|
500W
|
MAXIMUM OUTPUT POWER (Typ.)
|
550W for 60 sec. / surge power 1000W for 30 cycles (112, 212 models : 495W for 60 sec. / surge power 900W for 30 cycles)
|
AC VOLTAGE
|
Factory setting set at 110VAC
|
Factory setting set at 230VAC
|
100 / 110 / 115 / 120VAC selectable by setting button S.W
|
200 / 220 / 230 / 240VAC selectable by setting button S.W
|
FREQUENCY
|
Factory setting set at 110VAC
|
Factory setting set at 230VAC
|
60±0.1Hz 50/60Hz selectable by setting button S.W
|
50±0.1Hz 50/60Hz selectable by setting button S.W
|
WAVEFORM
|
True sine wave (THD<3%) at rated input voltage
|
AC REGULATION (Typ.) Note.1
|
±3%
|
FRONT PANEL INDICATOR
|
Fault and operation status, Charger status, Battery capacity
|
INPUT
|
BAT. VOLTAGE
|
12V
|
24V
|
48V
|
12V
|
24V
|
48V
|
VOLTAGE RANGE Note.3,5
|
10.5 ~ 15VDC
|
21 ~ 30VDC
|
42 ~ 60VDC
|
10.5 ~ 15VDC
|
21 ~ 30VDC
|
42 ~ 60VDC
|
DC CURRENT (Typ.) Note.7
|
50A
|
30A
|
15A
|
50A
|
30A
|
15A
|
NO LOAD CURRENT DRAW (Typ.)
|
1.25A
|
0.63A
|
0.32A
|
1.25A
|
0.63A
|
0.32A
|
OFF MODE CURRENT DRAW (Typ.)
|
?1mA
|
EFFICIENCY (Typ.) Note.2
|
85%
|
87%
|
87%
|
86%
|
88%
|
88%
|
OUTPUT PROTECTION
|
OVER TEMPERATURE
|
Shut down o/p voltage, re-power on to recover
|
OUTPUT SHORT
|
Shut down o/p voltage, re-power on to recover
|
OVER LOAD (Typ.)
|
110% load for 60 sec.
|
Protection type : Shut down o/p voltage, re-power on to recover
|
BATTERY SECTION
|
CHARGER CURRENT (Typ.)
|
30A
|
17A
|
8.5A
|
30A
|
17A
|
8.5A
|
BATTERY TYPE
|
Open & sealed Lead Acid
|
FUSE
|
40A*2
|
40A*1
|
20A*1
|
40A*2
|
40A*1
|
20A*2
|
BAT. LOW ALARM Note.3
|
11.3V
|
22.5V
|
45V
|
11.3V
|
22.5V
|
45V
|
BAT. LOW SHUTDOWN Note.3
|
10.5V
|
21V
|
42V
|
10.5V
|
21V
|
42V
|
REVERSE POLARITY
|
By internal fuse open
|
MPPT / SOLAR SECTION
|
MPPT CHARGER EFFICIENCY (Typ.)
|
98%
|
OPEN CIRCUIT VOLTAGE RANGE
|
35 ~ 50V
|
45 ~ 90V
|
90 ~ 160V
|
35 ~ 50V
|
45 ~ 90V
|
90 ~ 160V
|
MPPT RANGE
|
25 ~ 50V
|
35 ~ 90V
|
70 ~ 160V
|
25 ~ 50V
|
35 ~ 90V
|
70 ~ 160V
|
SOLAR INPUT CURRENT (Typ.)
|
11A
|
7A
|
4.5A
|
11A
|
7A
|
4.5A
|
SOLAR INPUT POWER (Typ.)
|
500W
|
GENERAL SECTION
|
ENVIRONMENT
|
WORKING TEMP. Note.4
|
-20 ~ +40? @ 100% load ; 60? @ 50% load
|
WORKING HUMIDITY
|
20% ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-30 ~ +70? / -22 ~ +158oF, 10 ~ 95% RH
|
VIBRATION
|
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
|
SAFETY
& EMC
|
LVD
|
None
|
EN60950-1 (LVD)
|
WITHSTAND VOLTAGE
|
Bat I/P – AC O/P:3.0KVAC AC O/P – FG:1.5KVAC
|
ISOLATION RESISTANCE
|
Bat I/P – AC O/P, Bat I/P – FG, AC O/P – FG: 100M ohms / 500VDC / 25?/ 70% RH
|
EMC EMISSION
|
Compliance to FCC part 15 class B
|
Compliance to EN55022 class B
|
EMC IMMUNITY
|
None
|
Compliance to EN61000-4-2,3,8
|
OTHERS
|
MTBF
|
57.8K hrs min. MIL-HDBK-217F (25?)
|
DIMENSION
|
205*158*67mm (L*W*H)
|
PA
|
CKING
|
2.35Kg; 6pcs/15.1Kg/1.55CUFT
|
|
NOTE
|
1.THD is tested by rated power, linear load at 13V,26V,52V input voltage. 2.Efficiency is tested by 350W, linear load at 13V,26V,52V input voltage.
The tolerance of each voltage value by models is : 112/212?±0.5V ; 124/224?±1V ; 148/248?±2V.
Output derating capacity referenced by curve 1. 5.Input derating capacity referenced by curve 2.
All parameters not specified above are measured at rated load, 25? of ambient temperature.
DC current is tested by 500W, linear load at 12V,24V,48V input voltage.
|
Remote ON/OFF Connector : JST B-XH or equivalent
Pin No.
| Assignment
| Pin No.
| Assignment
|
1
| Battery Input NEG(-)
| 5
| FG
|
2
| Battery Input POS(+)
| 6
| Bat. Low Alarm Connector
|
3
| Solar Input NEGC(-)
| 7
| Remote ON/OFF Connector
|
4
| Solar Input POS(+)
|
| |