Wattage | 15W~1000W |
---|---|
Features |
|
Model No. Data Link | SD-15 / SD-25 / SD-50 / SD-100 / SD-150 / SD-200 / SD-350 / SD-500 / SD-1000 / RSD-30 / RSD-60 /RSD-100 / RSD-150 / RSD-200 / RSD-300 |
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for SD-15 / SD-25 / SD-50 / SD-100 / SD-150 / SD-200 / SD-350 / SD-500 / SD-1000 / RSD-100 / RSD-150 / RSD-200 / RSD-300 above.
SD-15 Series Features:
15W Single Output DC-DC Converter
- 2:1 wide input range
- Protections: Short circuit/Over load /voltage
- Built-in EMI filter, low ripple noise
- 100% full load burn-in test
- Low cost
- High Reliability
- 2 year warranty
MODEL | SD-15A-05 | SD-15B-05 | SD-15C-05 | SD-15A-12 | SD-15B-12 | SD-15C-12 | SD-15A-24 SD-15B-24 | SD-15C-24 | ||
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | ||||||
RATED CURRENT | 3A | 1.25A | 0.625A | |||||||
CURRENT RANGE | 0 ~ 3A | 0 ~ 1.25A | 0 ~ 0.625A | |||||||
RATED POWER | 15W | 15W | 15W | |||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | |||||||
VOLTAGE ADJ.RANGE | 4.75~5.5VDC | 10.8~13.2VDC | 21.6~26.4VDC | |||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | |||||||
LINE REGULATION | ±0.5% | ±0.3% | ±0.2% | |||||||
LOAD REGULATION | ±0.5% | ±0.3% | ±0.2% | |||||||
SETUP, RISE ,HOLD UP TIME | 2.5s, 25ms,— 12VDC/24VDC/48VDC at full load | |||||||||
INPUT | VOLTAGE RANGE | A: 9.2 ~18VDC B:18 ~ 36VDC C:36~72VDC | ||||||||
EFFICIENCY(Typ.) | 68% | 76% | 75% | 72% | 76% | 79% | 70% | 77% | 78% | |
DC CURRENT(Typ.) | 1.9A/12VDC 0.9A/24VDC 0.45A/48VDC | |||||||||
PROTECTION | OVER LOAD | 105 ~160% rated output power | ||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8~ 16.2V | 27.6 ~ 32.4V | |||||||
Protection type : Shut off o/p voltage, clamping by zener diode | ||||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60? (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85?, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/? (0 ~ 50?) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min.each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note 4) | WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH | |||||||||
EMC EMISSION | Compliance to EN55022(CISPR22) | |||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,6,8, EN55024, light industry level, criteria A | |||||||||
OTHERS | MTBF | 644.2K hrs min.(SD-15A) 652.5K hrs min.(SD-15B) 653.5K Hrs min.(SD-15C) MIL-HDBK-217F (25?) | ||||||||
DIMENSION | 78*51*28mm (L*W*H) | |||||||||
PACKING | 0.18Kg,60 PCS/11.8Kg | |||||||||
NOTE | All parameters NOT specially mentioned are measured at normal input, rated load and 25°C of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance: includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into final equipment. All the EMC tests have been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how toperform these EMC tests, please refer to “EMI testing of component power supplies.” (available on http://www.meanwell.com) |