Wattage | 5W~60W |
---|---|
Features |
|
Model No. Data Link |
Fixed GS05U-USB / GS05E-USB / GS06U / GS06E / GS15U / GS15E / GST18U / GST18E / GST25U / GST25E / GST36U / GST36E Slim SGA12U / SGA12E / SGA18U / SGA18E / SGA25U / SGA25E / SGA40U / SGA40E / SGA60U / SGA60E Interchangeable GE12 / GE18 / GE24 / GE30 |
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for GS05U-USB / GS05E-USB / GS06U / GS06E / GS15U / GS15E / GST18U / GST18E / GST25U / GST25E / GST36U / GST36E / SGA12U / SGA12E / SGA18U / SGA18E / SGA25U / SGA25E / SGA40U / SGA40E / SGA60U / SGA60E / GE12 / GE18 / GE24 / GE30 above.
GS05U-USB Features:
5W AC-DC Industrial Adaptor
- Universal AC input / Full range
- 2 pole USA plug
- No load power consumption <0.075W
- Energy efficiency Level Ⅵ
- Comply with EISA 2007/DoE
- Compact size
- Class II power (without earth pin)
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Pass LPS
- 100% full load burn-in test
- Fully enclosed plastic case
- Low cost, high reliability
- 2 years warranty
ORDER NO. | GS05U-USB | |
OUTPUT | SAFETY MODEL NO. | GS05U |
DC VOLTAGE Note.2 | 5V | |
RATED CURRENT | 1.00A | |
CURRENT RANGE | 0 ~ 1.00A | |
RATED POWER | 5W | |
RIPPLE & NOISE (max.) Note.3 | 90mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±4.0% | |
LINE REGULATION Note.5 | ±1.0% | |
LOAD REGULATION Note.6 | ±4.0% | |
SETUP, RISE, HOLD UP TIME | 1500ms, 20ms, 15ms at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 74% | |
AC CURRENT | 0.15A / 100VAC | |
INRUSH CURRENT (max.) | 35A / 230VAC | |
LEAKAGE CURRENT(max.) | 0.25mA / 240VAC | |
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 105 ~ 160% rated output voltage, detect on main control IC | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +50?(Refer to “Derating curve”) |
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85?, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03% / ? (0 ~ 40?) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC (Note. 7) | SAFETY STANDARDS | UL60950-1, CSA C22.2 approved |
WITHSTAND VOLTAGE | I/P-O/P:4242VDC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH | |
EMI CONDUCTION & RADIATION | Compliance to FCC part 15 Class B | |
OTHERS | MTBF | 1100Khrs min. MIL-HDBK-217F(25?) |
DIMENSION | 41.86*32.76*23.8mm (L*W*H) | |
PACKING | 26g ; 102pcs / 5Kg / CARTON | |
CONNECTOR | PLUG | USB Type A |
NOTE | 1.All parameters are specified at 115VAC input, rated load, 25? 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 0% to 100% rated load 7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) |