Mean Well Medical Adapter – Desktop External Switching Power Supply

Wattage 18W~220W
Features
  • Medical safety approved (2xMOPP), suitable for BF application with appropriate system consideration (B type)
  • Energy efficiency Level VI (GSM06/18/25/36/40/60 5~9V: Level V)
  • No load power consumption <0.1W~0.15W
  • Comply with EISA/DoE, NRCan, ErP and meet CoC Version 5
  • A type: Class I (with FG), equipped IEC320-C14; B type: Class II (without FG), equipped IEC320-C8
  • DC plug changeable (MOQ may be required)
  • 3 years warranty
Model No. Data Link GSM18B / GSM25B / GSM36B / GSM40A / GSM40B / GSM60A / GSM60B / GSM90A / GSM90B / GSM120A / GSM120B / GSM160A / GSM160B / GSM220A / GSM220B

For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.

You can download and/or view the PDF specifications for GSM18B / GSM25B / GSM36B / GSM40A / GSM40B / GSM60A / GSM60B / GSM90A / GSM90B / GSM120A / GSM120B / GSM160A / GSM160B / GSM220A / GSM220B above.

GSM18B Series Features * Applications:

18W AC-DC High Reliability Medical Adaptor

  • Universal AC input / Full range
  • 2 pole AC inlet IEC320-C8
  • Medical safety approved (2 × MOPP between primary to secondary)
  • Suitable for BF application with appropriate system consideration
  • Low leakage current <50μA
  • No load power consumption<0.1W
  • Energy efficiency Level Ⅵ( except 5-9V for Level Ⅴ)
  • Comply with EISA 2007/DoE,NRCan,AU/NZ MEPS,EU ErP and meet CoC Version 5
  • High efficiency up to 88%
  • High operating temperature up to +60℃
  • Class Ⅱ power (without earth pin)
  • Protections: Short circuit / Overload / Over voltage
  • Fully enclosed plastic case
  • LED indicator for power on
  • Optional lock type DC plug
  • 100% full load burn-in test
  • 3 years warranty

 

GSM18B Series Description

  • Blood glucose meter
  • Blood pressure meter
  • Nebulizer
  • Inhaler
  • Portable medical device

GSM18B is a highly reliable, 18W desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 5VDC and 48VDC that can satisfy the demands for various kinds of miniature medical devices. The circuitry design meets the international medical standards (2 × MOPP), having an ultra low leakage current (<50μA), fitting the medical devices in direct electrical contact with the patients.

With the efficiency up to 88% and the extreme low no-load power consumption below 0.1W, GSM18B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP and meet Code of Conduct(CoC) Version 5 ; the supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM18B is approved with the international medical safety certificates.

 

ORDER NO. GSM18B05-P1J GSM18B07-P1J GSM18B09-P1J GSM18B12-P1J GSM18B15-P1J GSM18B18-P1J GSM18B24-P1J GSM18B48-P1J
OUTPUT SAFETY MODEL NO. GSM18B05 GSM18B07 GSM18B09 GSM18B12 GSM18B15 GSM18B18 GSM18B24 GSM18B48
DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V
RATED CURRENT 3A 2A 2A 1.5A 1.2A 1A 0.75A 0.375A
CURRENT RANGE 0 ~ 3A 0 ~ 2A 0 ~ 2A 0 ~ 1.5A 0 ~ 1.2A 0 ~ 1A 0 ~ 0.75A 0 ~ 0.375A
RATED POWER (max.) 15W 15W 18W 18W 18W 18W 18W 18W
RIPPLE & NOISE (max.) Note.3 60mVp-p 80mVp-p 80mVp-p 120mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.) 16ms / 230VAC 16ms / 115VAC at full load
INPUT VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 80% 83% 84% 85% 85.5% 86% 87% 88%
AC CURRENT (Typ.) 0.5A / 115VAC 0.25A / 230VAC
INRUSH CURRENT (Typ.) 55A / 230VAC 30A / 115VAC
LEAKAGE CURRENT(max.) Touch current < 50?A/264VAC
PROTECTION OVERLOAD 105 ~ 170% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 5.25 ~ 7.5V 7.88 ~ 10.13V 9.45 ~ 12.6V 12.6 ~ 17.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -25 ~ +60? (Refer to “Derating Curve”)
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85?, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03% / ? (0~40?)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note. 8) SAFETY STANDARDS ANSI/AAMI ES60601-1 / 60601-1-11, TUV EN60601-1 / 60601-1-11 approved
WITHSTAND VOLTAGE I/P-O/P:4KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH
EMC EMISSION Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A
OTHERS MTBF 796.7K hrs min. MIL-HDBK-217F(25?)
DIMENSION 79*54*33mm (L*W*H)
PACKING 205g ; 60pcs / 13.3Kg / CARTON
CONNECTOR PLUG See page 3 ; Other type available by customer requested
CABLE See page 3 ; Other type available by customer requested
NOTE All parameters are specified at 230VAC input, rated load, 25? 70% RH ambient. DC voltage: The output voltage set at point measure by plug terminal & 50% load. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1uf & 47uf capacitor. Tolerance: includes set up tolerance, line regulation, load regulation. Line regulation is measured from low line to high line at rated load. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. Derating may be needed under low input voltage. Please check the derating curve for more details. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)