Wattage | 5W~60W |
---|---|
Features |
|
Model No. Data Link | NSD05 / NSD10-S / NSD10-D / NSD15-S / NSD15-D / NID30 / NID60 |
For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.
You can download and/or view the PDF specifications for NSD05 / NSD10-S / NSD10-D / NSD15-S / NSD15-D / NID30 / NID60 above.
NSD05-S Series Features:
5W DC-DC Regulated Single Output
- Wide 4:1 DC input range
- Protections: Short circuit / Overload / Over voltage
- 1000VDC 1/O isolation
- Cooling by free air convection
- Built-in remote ON-OFF contro
- 100% full load burn-in test
- Low cost
- High reliability
- 2 years warranty
MODEL | NSD05-12S3 | NSD05-12S5 | NSD05-12S12 | NSD05-12S15 | NSD05-48S3 | NSD05-48S5 | NSD05-48S12 | NSD05-48S15 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 3.3V | 5V | 12V | 15V |
RATED CURRENT | 1.2A | 1A | 0.42A | 0.33A | 1.2A | 1A | 0.42A | 0.33A | |
CURRENT RANGE | 0 ~ 1.2A | 0 ~ 1A | 0 ~ 0.42A | 0 ~ 0.33A | 0 ~ 1.2A | 0 ~ 1A | 0 ~ 0.42A | 0 ~ 0.33A | |
RATED POWER | 3.96W | 5W | 5.04W | 4.95W | 3.96W | 5W | 5.04W | 4.95W | |
CAPACITIVE LOAD (max.) | 1000uF | 1000uF | 120uF | 120uF | 1000uF | 1000uF | 120uF | 120uF | |
RIPPLE & NOISE (max.) Note.2 | 75mVp-p | ||||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% max. | ||||||||
LINE REGULATION | ±1.0% | ||||||||
LOAD REGULATION | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP TIME | 80ms/RATED DC INPUT at full Load | ||||||||
INPUT | RATED DC INPUT | 12VDC | 48VDC | ||||||
VOLTAGE RANGE | 9.2 ~ 36VDC | 18 ~ 72VDC | |||||||
EFFICIENCY (Typ.) | 72% | 76% | 82% | 83% | 75% | 78% | 83% | 85% | |
DC CURRENT | 0.7A/12VDC | 0.2A/48VDC | |||||||
SHUTDOWN IDLE CURRENT | 5mA/12VDC 5mA/48VDC | ||||||||
PROTECTION | OVERLOAD | Above 105% rated output power | |||||||
Protection type : Over power limiting, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE(CLAMP) | 3.8 ~ 4.6V | 5.6 ~ 6.8V | 13.5 ~ 16.5V | 16.2 ~ 19.8V | 3.8 ~ 4.6V | 5.6 ~ 6.8V | 13.5 ~ 16.5V | 16.2 ~ 19.8V | |
SHORT CIRCUIT | Recovers automatically after fault condition is removed | ||||||||
FUNCTION | ON/OFF CONTROL | Logic “1” or open circuit : ON Logic “0” or short to PIN2 : OFF | |||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70? | |||||||
WORKING HUMIDITY | 0% ~ 95% RH max. | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85?, 0 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/? (0~60?) | ||||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | IEC60950-1 CB approved by TUV | |||||||
ISOLATION VOLTAGE | I/P-O/P:1KVDC | ||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH | ||||||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B | ||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8; EN55024, light industry level, criteria A | ||||||||
OTHERS | MTBF | 914.4K hrs min. MIL-HDBK-217F (25?) | |||||||
DIMENSION | 40.6*25.4*8.3mm (1.6″*1″*0.327″) (L*W*H) | ||||||||
PACKING | 0.007Kg; 700pcs/5.9Kg/0.97CUFT | ||||||||
NOTE | All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25? of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EM1 testing of component power supplies.” (as available on http://www.meanwell.com) To insure proper operation, a 47uF/100V electrolytic capacitor with Esr <1? must be added to the input line. 6.EMC filter suggestion(TBD): 5.5uH + + + Vin 680uF PSU Vo - - |