Mean Well PCB Type DC/DC Converter

Wattage 5W~45W
Features
  • 2:1 wide input range
  • CE declaration
  • Built-in systems and low cost
Model No. Data Link PSD-05 / PSD-15 / PSD-30 / PSD-45

For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.

You can download and/or view the PDF specifications for PSD-05 / PSD-15 / PSD-30 / PSD-45 above.

PSD-05 Series Features:

5W Single Output DC-DC Converter

  • 2:1 wide input range
  • Protections:Short circuit/Over load /Over voltage/Over temperature
  • Built-in EMI filter, low ripple noise
  • 100% full load burn-in test
  • Fix switching frequency at 67KHz
  • High reliability 2 year warranty
  • Low cost
MODEL PSD-05-05 PSD-05-12 PSD-05-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 1A 0.45A 0.22A
CURRENT RANGE 0 ~ 1A 0 ~ 0.5A 0 ~ 0.25A
RATED POWER 5W 5.4W 5.28W
RIPPLE & NOISE (max.) Note.2 50mVp-p 100mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0%
LINE REGULATION ±1.0% ±1.0% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±0.5%
SETUP, RISE, HOLD UP TIME 1.2s, 20ms,— at full load
INPUT VOLTAGE RANGE 36 ~ 72VDC
EFFICIENCY(Typ.) 75% 78% 78%
DC CURRENT(Typ.) 0.15A/48V
PROTECTION OVERLOAD Above 105% rated output power
Protection type : Fold back current limiting, recovery automatically after fault condition is removed
OVER VOLTAGE 5.75~ 6.75V 13.8~16.2V 27.6~ 32.4V
Protection type : Hiccup mode, recovery automatically after fault condition is removed
OVER TEMPERATURE Hiccup mode, recovery automatically after temperature goes down
ENVIRONMENT WORKING TEMP. -10 ~ +60? (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85?, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.05%/? (0 ~ 50?)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) WITHSTAND VOLTAGE I/P-O/P:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 6, 8 ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
OTHERS DIMENSION 75*40*20mm (L*W*H)
PACKING 50mg;120pcs/6.25Kg/1CUFT
NOTE All parameters NOT specially mentioned are measured at 48VDC input, rated load and 25? of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)