Mean Well True Sine Wave Series Off Grid DC/AC Power Inverter

Wattage 200W~3000W
Features

TS Features

  • True sine wave output, suitable for motor related applications
  • High surge power up to 200%
  • Output voltage / frequency adjustable
  • Conformal coating (except for TS-200/400)
  • 3 years warranty

TN Features

  • True sine wave with solar charger & by-pass function
  • High surge power up to 200%
  • Output voltage / frequency adjustable
  • Conformal coating (except for TS-200/400)
  • Computer-based monitoring software, recommended for Windows 7 and Windows 8 Operating System (English and Chinese version)
  • 3 years warranty

IRC Features

  • Remote controller for TS-700~3000 , TN-1500~3000
Model No. Data Link TS-200 / TS-400 / TS-700 / TS-1000 / TS-1500 / TS-3000   TN-1500 / TN-3000   IRC1 / IRC2 / IRC3

For more information or to speak with a Power 277 professional please call toll free: (877) 878-2348 or for international calls (001) 702-987-3111.

You can download and/or view the PDF specifications for TS-200 / TS-400 / TS-700 / TS-1000 / TS-1500 / TS-3000 TN-1500 / TN-3000 IRC1 / IRC2 / IRC3 above.

TS-700 Series

700W True Sine Wave DC-AC Power Inverter Features:

  • True sine wave output (THD<3%)
  • High surge power up to 1400W
  • Standby saving mode can be selectable
  • Front panel indicator for operation status
  • Built-in fan ON-OFF control function
  • Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Reverse polarity / Overload
  • Application : Home appliance, power tools, office and portable
  • High efficiency up to 91%
  • Power ON-OFF switch
  • Equipment, vehicle and yacht …etc.
  • 3 years warranty
MODEL TS-700-112 TS-700-124 TS-700-148 TS-700-212 TS-700-224 TS-700-248
OUTPUT RATED POWER (Typ.) 700W
MAXIMUM OUTPUT POWER (Typ.) 800W for 180 sec. / 1050W for 10 sec. / surge power 1400W for 30 cycles
AC VOLTAGE Factory setting set at 110VAC Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY 60±0.1Hz 50/60Hz selectable by setting button S.W 50±0.1Hz 50/60Hz selectable by setting button S.W
WAVEFORM Note.6 True sine wave (THD<3%)
AC REGULATION (Typ.) ±3.0%
SAVING MODE (Typ.) Default disabled. Load?5W will be changed to standby mode
FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status
INPUT BAT. VOLTAGE 12V 24V 48V 12V 24V 48V
VOLTAGE RANGE (Typ.)Note.3,5 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC
DC CURRENT (Typ.) 75A 38A 19A 75A 38A 19A
NO LOAD DISSIPATION (Typ.) ?6W @ standby saving mode
OFF MODE CURRENT DRAW ?1mA
EFFICIENCY (Typ.) Note.1 86% 88% 89% 89% 90% 91%
BATTERY TYPES Open & sealed Lead Acid
BATTERY INPUT PROTECTION FUSE 40A*3 30A*2 20A*2 40A*3 30A*2 20A*2
BAT. LOW ALARM 11.3±4% 22.5±4% 45±4% 11.3±4% 22.5±4% 45±4%
BAT. LOW SHUTDOWN 10.5±4% 21±4% 42±4% 10.5±4% 21±4% 42±4%
BAT. POLARITY By internal fuse open
OUTPUT PROTECTION OVER TEMPERATURE 80?± 5? 75?± 5?
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode
OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION Optional (Only type F) None
ENVIRONMENT WORKING TEMP. Note.4 0 ~ +40? @ 100% load ; +60? @ 50% load
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -30 ~ +70? / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS Design refer to UL458 None
LVD None EN60950-1
WITHSTAND VOLTAGE Bat I/P – AC O/P:3.0KVAC AC O/P – FG:1.5KVAC
ISOLATION RESISTANCE AC O/P-FG , Bat I/P-FG:100M Ohms / 500VDC / 25?/ 70% RH
EMC EMISSION Compliance to FCC class A Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMC IMMUNITY None Compliance to EN61000-4-2,3,8
OTHERS MTBF 74.4K hrs min. MIL-HDBK-217F (25?)
DIMENSION 295*184*70mm (L*W*H)
PACKING 3.8Kg; 2pcs/8.6Kg/1.27CUFT
NOTE Efficiency is tested by 530W, linear load at 13V, 26V, 52V input voltage. All parameters not specified above are measured at rated load, 25? of ambient temperature and set to factory setting. 3.lnput derating capacity referenced by curve 2. Output derating capacity referenced by curve 1. The tolerance of each voltage value by models is:112/212?±0.5V;124/224?±1V;148/248?±2V 6.THD is tested by 700W, linear load at 13,26,52V input voltage.